DC12V 8-16Channel RS485 Relay Delay Module Modbus RTU PLC Expaning Board

$9.78 (-40%)

3760

Visit store
Items for sale
About us
Product Details
8 Channel RS485 Relay Module/DIN Rail Case
Features:
1 Working voltage: DC 12V
2 Working current: standby 12MA, 1 relay conduction 40MA, 2 relay conduction 68MA, 3 relay conduction 94MA, 4 relay conduction 120MA, 5 relay conduction 148MA, 6 relay conduction 174MA, 7 Two relays conduct 199MA, 8 relays conduct 224MA
3 Open, close, jog, self-lock, interlock, and delay six working modes
4 MODBUS command (default) and AT command two command control modes
5 The maximum delay under MODBUS command is 255 seconds, the maximum delay under AT command is 9999 seconds
6 AT commands can be input by serial port super terminal (serial assistant); MODBUS commands can be input by “Modbus Poll” besides serial port super terminal input
7 In MODBUS command mode, up to 64 devices can be used in parallel
8 The default baud rate is 9600BPS, you can select the baud rate 2400 4800 19200 BPS through the jumper
9 Size: 100 * 72 * 20mm (circuit board); 120 * 88 * 42mm (with rail box)
10 Weight: 120g (circuit board); 198g (with rail box)
11 Maximum load: 10A/250VAC, 10A/125VAC, 10A/30VDC, 10A/28VDC, 10A/12VDC
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 100 mm PCB boards
Net weight: 72g
Installation: DIN35 and C45 rail
Glossary:
NO         : Relay normally open contact
COM       : Relay common contact
NC         : Relay normally closed contact
Open       : NO connection COM, NC disconnect COM
Close       : NO disconnect COM, NC connection COM
Momentary : Enter the Momentary command, the Rreceiver Relay is Open, delay of 0.5 seconds after, Relay is Close;
Toggle  : Enter the Toggle command, the Rreceiver Relay is Open, Enter the Toggle command again, Relay is Close;
Latched : Enter the Channel 1 Latched command, the receiver Channel 1 is Open, the Channel 2 is Close.
Enter the Channel 2 Latched command the receiver Channel 2 is Open, the Channel 1 is Close.
Enter the Channel 3 Latched command the receiver Channel 1 is Close, the Channel 2 is Close.
Delay : Enter the Delay command, the Rreceiver Relay is Open, delay of 0-9999 seconds(MODBUS command is 0-255 seconds )after, Relay is Close;
During the delay, Eter the Close command, immediately close the relay
Slave ID: A0-A5 is the slave ID, you can choose 64 different slave ID.
Under the MODBUS command mode,the slave ID must be correct
1 This version has 2 Command modes, MODBUS RTU Command and AT Command.  2 The default Command is the MODBUS RTU Command, compatible with older versions.
3 Switch to AT command by shorting the M0 pad.
4 The default baud rate is 9600BPS. You can also select the baud rate by shorting the M1 and M2 pads.
command Description, Please refer to “8 Channel Rail RS485 Relay commamd”
Typical applications:
1.When controlling a module, you can use the MODUBS RTU instruction or the AT instruction. In AT command mode, the dial switch (slave address) is invalid and can only control one module at a time.
2.MODBUS command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
Wiring Diagram:
1 DC 12V control circuit,Wiring diagram below. “LOAD” may be camera,LED lights, fans, motors and other DC 12V equipment
2 DC 1-110VAC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). “LOAD” may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipment
Package Included:
1 x 8 Channel RS485 Relay Module
16 Channel RS485 Relay Module/DIN Rail Case
Features:
1: DC 12V power supply
2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 148MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 225MA.etc
3: “open” “close”  “Momentary” “Self-locking” “Interlock” “Delay” 6 Commands
4: Two instruction-control mode : MODBUS RTU command and AT command
5: Under the “Delay” command ,the maximum delay is 255 seconds;
Under the AT command ,the maximum delay is 9999 seconds
6 MODBUS commands can be made serial HyperTerminal (serial assistant)  OR “Modbus Poll” Enter; AT commands can be made serial HyperTerminal (serial assistant) Enter;
7 Under the MODBUS command mode, it can support up to 64 devices in parallel
8 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS
9  Size: 180 * 72 * 20mm(Only PCB Board);184 * 88* 42mm(with Din Rail Box)
10 Weight: 230g(Only PCB Board);358g(with Din Rail Box)
11 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 180 mm PCB boards
Net weight: 128g
Installation: DIN35 and C45 rail
Glossary:
NO : Relay normally open contact
COM : Relay common contact
NC : Relay normally closed contact
Open : NO connection COM, NC disconnect COM
Close : NO disconnect COM, NC connection COM
Momentary : Enter the Momentary command, the Rreceiver Relay is Open, delay of 0.5 seconds after, Relay is Close;
Toggle  : Enter the Toggle command, the Rreceiver Relay is Open, Enter the Toggle command again, Relay is Close;
Latched : Enter the Channel 1 Latched command, the receiver Channel 1 is Open, the Channel 2 is Close.
Enter the Channel 2 Latched command the receiver Channel 2 is Open, the Channel 1 is Close.
Enter the Channel 3 Latched command the receiver Channel 1 is Close, the Channel 2 is Close.
Delay : Enter the Delay command, the Rreceiver Relay is Open, delay of 0-9999 seconds(MODBUS command is 0-255 seconds )after, Relay is Close;
During the delay, Eter the Close command, immediately close the relay
Slave ID: A0-A5 is the slave ID, you can choose 64 different slave ID.
Under the MODBUS command mode,the slave ID must be correct
1 This version has 2 Command modes, MODBUS RTU Command and AT Command.  2 The default Command is the MODBUS RTU Command, compatible with older versions.
3 Switch to AT command by shorting the M0 pad.
4 The default baud rate is 9600BPS. You can also select the baud rate by shorting the M1 and M2 pads.
command Description, Please refer to “16 Channel Rail RS485 Relay commamd”
Typical applications:
1 When controlling a module, you can use the MODUBS RTU instruction or the AT instruction. In AT command mode, the dial switch (slave address) is invalid and can only control one module at a time.
MODBUS command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
Wiring Diagram:
1 DC 12V control circuit,Wiring diagram below. “LOAD” may be camera,LED lights, fans, motors and other DC 12V equipment
2 DC 1-110VAC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). “LOAD” may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipment
Package Included:
1PCS*
12 Channel RS485 Relay Module
Payment Method
Shipping Policy
Returns & Refund Policy
Feedback
Payment Method
EBAY Managed Payment.
But we only
Accept
your
Ebay Address
, please Make sure it’s 100% right.
Payment must be received in 5 business days of auction closing.
Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
Shipping Policy
1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
3. All package need to wait 30 days,Please take care it.Less than 30 days,we can’t take a refund.
Returns & Refund Policy
All package need to
wait 30 days
(US only n
eed 7-10 days)
,
Please take care it.Less than 30 days,we can’t take a refund
.
If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it.
If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.
Feedback
We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.

Main Menu